<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-20 18-34-17
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 3/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 65 kHz 3792 0,1055
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,8 dBr 5,32 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 65 kHz MIN: 13 kHz % above 76 kHz: 0,1055 Acquired: 2025/08/20 18.33.13 Total samples: 3792 Equivalent time: 0:03:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 6,2 dBr MIN: 3,8 dBr AVE: 5,32 dBr % above 12,2 dBr: 0,0 Last value: 6,2 dBr (2025/08/20 18.33.12) 18.20 18.22 18.24 18.26 18.28 18.30 18.32 0 2 4 6 Pm [dBr]